Application range
The Nernst N32-FZSX integrated oxygen analyzer is an integrated structure product. It can be widely used in the detection of oxygen content in the combustion process of various industries such as petroleum, chemical industry, metallurgy, electric power, and incineration. The Nernst N32-FZSX integrated oxygen analyzer can directly monitor the oxygen content in the flue gas of boilers, sintering furnaces, heating furnaces, etc. during or after combustion.
Technical characteristics
• Input function: The integrated oxygen analyzer displays the measured oxygen content in real time.
• Output control: The analyzer has a 4-20mA current output signal.
• Measurement range: -33.4mV~280.0mV (750°C).
• Alarm setting: The analyzer has arbitrarily adjustable high and low oxygen alarm output.
• Field connection: A power cord and a signal line are directly connected to the analyzer.
• Intelligent system: The analyzer can complete the functions of various settings according to the predetermined settings.
• Display function: The analyzer can display real-time oxygen content, probe temperature, real-time oxygen millivolt value and other 8 status displays.
• Safety function: When the furnace is out of use, the user can control to turn off the heater of the probe to ensure safety during use.
• Easy installation: The probe and the analyzer adopt an integrated design, which is easy to install.
Technical parameter
Power supply |
Analyzer power |
Probe heating method |
Probe heating temperature |
AC 200V~260V |
25W+50W (probe) |
PID control |
750°C±1°C |
Display method |
Oxygen measurement |
Accuracy |
reaction speed |
LED display |
-33.4mV~280.0mV (750°C) | Measurement accuracy ±1%Repeat accuracy ±0.5% | Indirect heating measurement 3 secondsDirect heating for 30 seconds
Probe response speed 0.0001 seconds |
Display mode |
Output method |
Alarm function |
Reference gas |
Normal work fixed display oxygen concentration8 cyclable display modes | 4-20mA transmission output | High and low oxygen alarms can be set arbitrarily. | External supply |
working environment |
Operation interface |
Installation method |
|
Ambient temperature: 0~40°CRelative humidity: ≤85%
Surrounding environment: no strong magnetic field. No strong oscillation, flammable, corrosive gas. Places not exposed to strong sunlight. |
Three touch buttons |
In-line installation |
Product detail pictures:

Related Product Guide:
Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for Bottom price Palm O2 Oxygen Analyzer - Nernst N32-FZSX integrated oxygen analyzer – Litong, The product will supply to all over the world, such as: Morocco, Greenland, United Arab emirates, Be sure to feel cost-free to send us your specs and we are going to respond for you asap. We have got a experienced engineering team to serve for the every single comprehensive needs. Free samples may be sent for yourself personally to know far more facts. So that you can meet your desires, please actually feel cost-free to contact us. You could send us emails and call us straight. Additionally, we welcome visits to our factory from all over the world for much better recognizing of our corporation. nd merchandise. In our trade with merchants of several countries, we often adhere to the principle of equality and mutual advantage. It is our hope to market, by joint efforts, both trade and friendship to our mutual benefit. We look forward to getting your inquiries.