Factory Cheap Hot Oxygen Analyzer Probe - Nernst HGP series high pressure type oxygen probe – Litong
Factory Cheap Hot Oxygen Analyzer Probe - Nernst HGP series high pressure type oxygen probe – Litong Detail:
Application range
The Nernst HGP series high pressure type oxygen probe is suitable for high-pressure steam boilers, nuclear steam boilers, nuclear power boilers.
Positive pressure variable pressure 0~10 atmospheres, negative pressure variable range -1~0 atmospheres.
The signal of the pressure sensor on the oxygen probe can be fed back to the analyzer according to the pressure change,and the oxygen content in the measured gas can be measured with high precision according to different pressures.The oxygen content value can be displayed correctly.
Specifications and technical parameters
• Model: HGP series high pressure type oxygen probe
• Shell material: 316 L stainless steel
• Application flue gas temperature: below 900°C
• Temperature control: The probe has its own heater to keep the temperature of the zirconium head constant.
• Thermocouple: Type K
• Heating time: about 15 to 30 minutes to reach the rated temperature of 700°C. (Related to flue gas temperature)
• Installation and connection: The probe comes with 1.5″BSP or NPT thread. The user can process the matching flange of the furnace wall according to the attached drawing in the instruction manual.
• Reference gas: The gas pump in the analyzer supplies about 50 ml/min. Use the gas for the instrument and supply the gas through the pressure reducing valve and float flow meter provided by the user. The manufacturer provides the PVC connecting pipe from the float flowmeter to the sensor and the connector at the sensor end with the transmitter.
• Gas connection pipe: PVC pipe with an outer diameter of 1/4″ (6.4mm) and an inner diameter of 4 (mm).
• Check gas connection: The sensor has an air inlet that can pass check gas. When it is not checked, it is closed by a bulkhead. When calibrating the air, the flow rate is controlled at about 1000 ml per minute. The manufacturer provides 1/8″NPT threaded pipe joints that can be connected to PVC pipes.
• Zirconium battery life: 4-6 years of continuous operation. It depends on the flue gas composition and temperature. Intermittent operation will affect the service life, and the heater should be kept running continuously.
• Response time: less than 4 seconds
• Filter: Stainless steel movable type. Filter outer diameter ¢42 (mm)
• Probe protection tube outer diameter: ¢32 (mm)
• Probe junction box temperature: <130°C
• Probe electrical connection: direct plug socket type or aviation plug socket.
• Weight: 0.6Kg plus 0.33Kg/100mm length.
• Calibration: After the initial installation of the system is stable, it needs to be checked once.
• Length:
Standard model | Explosion-proof model | Length |
HGP0050 | HGP0050(EX) | 50mm |
HGP0150 | HGP0150(EX) | 150mm |
HGP0190 | HGP0190(EX) | 190mm |
HGP0250 | HGP0250(EX) | 250mm |
HGP0350 | HGP0350(EX) | 350mm |
HGP0500 | HGP0500(EX) | 500mm |
HGP0750 | HGP0750(EX) | 750mm |
HGP1000 | HGP1000(EX) | 1000mm |
HGP1500 | HGP1500(EX) | 1500mm |
Product detail pictures:
Related Product Guide:
We have now numerous great personnel members good at advertising, QC, and working with kinds of troublesome dilemma from the creation course of action for Factory Cheap Hot Oxygen Analyzer Probe - Nernst HGP series high pressure type oxygen probe – Litong, The product will supply to all over the world, such as: Namibia, Philippines, Croatia, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
By Agustin from Salt Lake City - 2018.09.08 17:09
With a positive attitude of "regard the market, regard the custom, regard the science", the company works actively to do research and development. Hope we have a future business relationships and achieving mutual success.
By Nydia from Algeria - 2018.10.01 14:14