Free sample for Annealing Furnace Oxygen Analyzer - Nernst NP32 portable trace oxygen analyzer – Litong
Free sample for Annealing Furnace Oxygen Analyzer - Nernst NP32 portable trace oxygen analyzer – Litong Detail:
Application range
The Nernst NP32 portable trace oxygen analyzer is the latest micro-oxygen analyzer designed and manufactured for the microelectronics industry.
The analyzer is used in vacuum welding furnaces, chip manufacturing in the electronics industry, biomedicine industry, bright annealing furnaces for precision parts, high-strength alloy tool coating processing equipment, etc., as well as processes that require oxygen control on various small equipment.The analyzer adopts the long-life, high-precision zirconia sheet structure principle, which can effectively measure micro-oxygen, and the measured micro-oxygen content can reach 10-30% ~ 100% oxygen content. It is especially suitable for equipment and processes with strict requirements for product process oxygen content control.
The NP32 portable trace oxygen analyzer provides real-time content of O2% (percentage) of flue gas in the furnace or flue gas and 12 other useful parameters.
The NP32 portable trace oxygen analyzer is also suitable for various other fields that need to measure high-precision oxygen content.
Technical characteristics
• Oxygen probe sensor: Built-in high-precision flake zirconia sensor.
• Multi-channel output control: The analyzer has two 4-20mA current output and computer communication interface RS232 or network communication interface RS485.
• Measurement range: The oxygen measurement range is 10-30 to 100% oxygen.
• Oxygen display unit: Percentage content% , PPM method , Scientific notation E-X% automatic conversion.
• Alarm setting: The analyzer has 1 general alarm output and 3 programmable alarm outputs.
• Automatic calibration: The analyzer has an automatic calibration function, and the user can customize the calibration time and number of calibrations according to their needs.
• Intelligent system: The analyzer can complete the functions of various settings according to the predetermined settings.
• Display output function: The analyzer has a strong function of displaying various parameters and a strong output and control function of various parameters.
• Safety function: When the furnace is out of use, the user can control to turn off the heater of the probe to ensure safety during use.
• Installation : The analyzer is integrated and convenient, no installation required.
Specifications
Inputs
• Built-in zirconia probe (oxygen sensor)
• Flue or spare thermometer type K, R, J, S type
• Pressure gas purge signal input
• Choice of two different fuels
• Safe operation control (only for heated probes)
Outputs
Two linear 4~20mA DC output
(Maximum load 1000Ω)
• The first output range (optional)
Linear output 0~1% to 0~100% oxygen content
Logarithmic output 0.1-20% oxygen content
Micro-oxygen output 10-25 to 10-1 oxygen content
• The second output range (can be selected from the following)
Flammability
hypoxia
Probe output voltage
carbon dioxide
Efficiency
flue temperature
Logarithmic oxygen
micro oxygen
Secondary Parameter Display
• Flammability
• Hypoxia
• Probe output voltage
• Carbon dioxide
• Efficient
• Flue temperaturefficient
• Probe temperature
• Probe impedance
• Ambient temperature
• Environment humidity
• Date
• Operation and maintenance time
Dust cleaning and standard gas calibration
The analyzer has 1 channel for dust removal and 1 channel for standard gas calibration or 2 channels for standard gas calibration output relays, and a solenoid valve switch that can be operated automatically or manually.
ary Parameter Display
AlarmsParameter Display
There are 14 general alarms with different functions and 3 programmable alarms. It can be used for warning signals such as the level of oxygen content, probe errors and measurement errors.
AccuracyP
± 1% of the actual oxygen reading with a repeatability of 0.5%.
For example, at 2% oxygen the accuracy would be ±0.02% oxygen.
Range of Local Indication
1.0 x 10-30% to 100% Oxygen
Serial/Network Interface
The analyzer has an RS232 or RS485 serial output port that can be directly connected to a computer terminal or printer, and the probe and analyzer can be diagnosed through the computer.
Reference gas
There is a miniature brushless motor vibration pump in the analyzer for reference gas.
Power Ruireqements
85VAC to 264VAC 3A
Operating Temperature
Operating Temperature -25°C to 55°C
Relative Humidity 5% to 95% (non-condensing)
Dimensions and Weight
300mm W x 220mm H x 320mm D 2.5kg
Product detail pictures:
Related Product Guide:
That has a positive and progressive attitude to customer's interest, our organization consistently improves our products quality to satisfy the demands of shoppers and further focuses on safety, reliability, environmental specifications, and innovation of Free sample for Annealing Furnace Oxygen Analyzer - Nernst NP32 portable trace oxygen analyzer – Litong, The product will supply to all over the world, such as: Slovenia, Costa Rica, Senegal, We aim to build a famous brand which can influence a certain group of people and light up the whole world. We want our staff to realize self-reliance, then achieve financial freedom, lastly obtain time and spiritual freedom. We do not focus on how much fortune we can make, instead we aim to obtain high reputation and be recognized for our products. As a result, our happiness comes from our clients satisfaction rather than how much money we earn. Ours team will do best for you always.
By Marina from Slovakia - 2017.06.25 12:48
Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
By Brook from Algeria - 2018.12.28 15:18