Working Principle of Acid Dew point analyzer and Its Application in Industrial Flue Gas Monitoring

In the field of industrial flue gas monitoring, the acid dew point analyzer plays a vital role as an important detection tool. It can not only help enterprises accurately understand the acid dew point temperature of flue gas, but also provide key data support for reducing equipment corrosion and optimizing the combustion process. This article will introduce in detail the working principle of the acid dew point analyzer and its application in industrial flue gas monitoring.

1. Working principle of acid dew point analyzer

The working principle of the acid dew point analyzer is based on the condensation characteristics of sulfuric acid vapor in flue gas. When burning high-sulfur fuel, part of the sulfur dioxide (SO2) formed after combustion will be further oxidized into sulfur trioxide (SO3), and SO3 will combine with water vapor in the flue gas to form sulfuric acid vapor. The condensation temperature of sulfuric acid vapor in flue gas is called acid dew point, which is much higher than water dew point. The more SO3 (or sulfuric acid vapor) content in flue gas, the higher the acid dew point. The acid dew point in flue gas can reach 140~160℃, or even higher.

The acid dew point analyzer reflects the SO3 content in the flue gas and the possible corrosion risk to the equipment by measuring the acid dew point temperature in the flue gas. In practical applications, the acid dew point analyzer usually contains a stainless steel probe with a conductivity mirror sensor installed on the probe. There are two electrodes on the surface of the sensor to detect any acid deposits. The temperature of the sensor surface is controlled by the flow rate of cooling compressed air. When the acid dew point probe is inserted into the flue gas and cooling compressed air is supplied, the temperature of the sensor surface drops until a sulfuric acid film begins to form on the mirror sensor surface. At this time, the instrument determines the temperature of the acid dew point by measuring the change in conductivity on the sensor surface.

1

2. Application of acid dew point analyzer in industrial flue gas monitoring

Corrosion Monitoring and Prevention:

The acid dew point temperature is an important indicator to measure the degree of low-temperature corrosion of the flue gas on the heating surface. The higher the dew point, the wider the corrosion range and the more serious the corrosion. Through the monitoring of the acid dew point analyzer, the enterprise can timely understand the acid dew point temperature of the flue gas, so as to take corresponding anti-corrosion measures, such as improving the material grade of the heating surface, optimizing the flue gas flow path, etc., to reduce equipment corrosion and extend the service life.

Combustion process optimization:

The monitoring data of the acid dew point analyzer can also provide guidance for the optimization of the combustion process. By comparing the acid dew point temperature under different combustion conditions, enterprises can adjust parameters such as fuel type and combustion method to reduce the SO3 content in the flue gas, thereby reducing the acid dew point temperature and reducing the risk of corrosion. At the same time, this also helps to improve combustion efficiency and reduce energy consumption.

Environmental compliance monitoring:

As environmental regulations become increasingly stringent, companies need to monitor flue gas emissions more strictly. As one of the important tools for flue gas monitoring, the acid dew point analyzer can help companies accurately understand the SO3 content in the flue gas, thereby ensuring that flue gas emissions meet environmental standards. This is of great significance to the sustainable development of enterprises.

3. Precautions for using the acid dew point analyzer

When using an acid dew point analyzer, pay attention to the following points:

Ensure measurement accuracy: Calibrate the acid dew point analyzer regularly to ensure its measurement accuracy. At the same time, during the measurement process, pay attention to avoid interference factors such as smoke, high wind speed, etc., which may affect the measurement results.

Choose a suitable installation location: The installation location of the acid dew point analyzer should be selected in an area with stable flue gas flow and representativeness to ensure the reliability of the measurement results.

Regular maintenance: Regularly maintain the acid dew point analyzer, including cleaning the probe, checking the sensor, etc., to ensure its long-term stable operation.

Acid dew point analyzers have broad application prospects in industrial flue gas monitoring. By accurately measuring the acid dew point temperature of flue gas, companies can timely understand the corrosion risk of flue gas, optimize the combustion process, and ensure environmental compliance. At the same time, when using acid dew point analyzers, attention should be paid to measurement accuracy, selection of appropriate installation locations, and regular maintenance. It is believed that with the continuous advancement of technology and the continuous expansion of application fields, acid dew point analyzers will play a more important role in industrial flue gas monitoring.