Professional China O2/Co Oxygen Content And Combustible Gas Two-Component Analyzer - Nernst N32-FZSX integrated oxygen analyzer – Litong
Professional China O2/Co Oxygen Content And Combustible Gas Two-Component Analyzer - Nernst N32-FZSX integrated oxygen analyzer – Litong Detail:
Application range
The Nernst N32-FZSX integrated oxygen analyzer is an integrated structure product. It can be widely used in the detection of oxygen content in the combustion process of various industries such as petroleum, chemical industry, metallurgy, electric power, and incineration. The Nernst N32-FZSX integrated oxygen analyzer can directly monitor the oxygen content in the flue gas of boilers, sintering furnaces, heating furnaces, etc. during or after combustion.
Technical characteristics
• Input function: The integrated oxygen analyzer displays the measured oxygen content in real time.
• Output control: The analyzer has a 4-20mA current output signal.
• Measurement range: -33.4mV~280.0mV (750°C).
• Alarm setting: The analyzer has arbitrarily adjustable high and low oxygen alarm output.
• Field connection: A power cord and a signal line are directly connected to the analyzer.
• Intelligent system: The analyzer can complete the functions of various settings according to the predetermined settings.
• Display function: The analyzer can display real-time oxygen content, probe temperature, real-time oxygen millivolt value and other 8 status displays.
• Safety function: When the furnace is out of use, the user can control to turn off the heater of the probe to ensure safety during use.
• Easy installation: The probe and the analyzer adopt an integrated design, which is easy to install.
Technical parameter
Power supply |
Analyzer power |
Probe heating method |
Probe heating temperature |
AC 200V~260V |
25W+50W (probe) |
PID control |
750°C±1°C |
Display method |
Oxygen measurement |
Accuracy |
reaction speed |
LED display |
-33.4mV~280.0mV (750°C) | Measurement accuracy ±1%
Repeat accuracy ±0.5% |
Indirect heating measurement 3 seconds
Direct heating for 30 seconds Probe response speed 0.0001 seconds |
Display mode |
Output method |
Alarm function |
Reference gas |
Normal work fixed display oxygen concentration
8 cyclable display modes |
4-20mA transmission output | High and low oxygen alarms can be set arbitrarily. | External supply |
working environment |
Operation interface |
Installation method |
|
Ambient temperature: 0~40°C
Relative humidity: ≤85% Surrounding environment: no strong magnetic field. No strong oscillation, flammable, corrosive gas. Places not exposed to strong sunlight. |
Three touch buttons |
In-line installation |
Product detail pictures:
Related Product Guide:
We persistently execute our spirit of ''Innovation bringing growth, Highly-quality making sure subsistence, Administration marketing reward, Credit history attracting clients for Professional China O2/Co Oxygen Content And Combustible Gas Two-Component Analyzer - Nernst N32-FZSX integrated oxygen analyzer – Litong, The product will supply to all over the world, such as: Mecca, French, St. Petersburg, If you are for any reason unsure which product to select, do not hesitate to contact us and we will be delighted to advise and assist you. This way we will be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We are looking for more and more customers to create the glorious future.